SLAC Magnetic Measurements Date: 01-11-2019 Time: 09:30:47 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_018 DATASET Number: 1 Tuning Stage: Tuning Run Number: 6 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X -1.000E-03 4.772E-06 63.613E-06 7.20000 7.19990 4426764 7.19995 4424125 7.19975 4426767 7.19985 4424127