SLAC Magnetic Measurements Date: 10-09-2018 Time: 10:36:14 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_015 DATASET Number: 1 Tuning Stage: Tuning Run Number: 6 Measurement Type: Long Coil Scans Operator: YL Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 -12.521E-06 -602.233E-06 10.00000 10.00000 4377852 10.00000 4354082 10.00000 4377852 10.00000 4354082 I2Y_VS_X 0.000E-03 -12.539E-06 -603.106E-06 10.00000 10.00000 4377852 10.00000 4354082 10.00000 4377852 10.00000 4354082 I2Y_VS_X 0.000E-03 -12.811E-06 -616.167E-06 10.00000 10.00010 4377850 10.00000 4354082 10.00005 4377851 10.00000 4354082