SLAC Magnetic Measurements Date: 02-12-2018 Time: 15:15:02 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_005 DATASET Number: 1 Tuning Stage: Tuning Run Number: 12 Measurement Type: Long Coil Scans Operator: YL Comment: Integrals for tuning; round 5 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -3.167E-06 -42.213E-06 7.20000 7.19975 4413325 7.19985 4418665 7.19965 4413327 7.19970 4418668 I1Y_VS_X 0.000E-03 -1.964E-06 -26.176E-06 7.20000 7.19940 4413332 7.19945 4418673 7.19930 4413334 7.19945 4418673 I1Y_VS_X 0.000E-03 -2.140E-06 -28.527E-06 7.20000 7.19920 4413336 7.19935 4418675 7.19915 4413337 7.19935 4418675 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 0.271E-06 3.619E-06 7.20000 7.19905 4413339 7.19930 4418676 7.19905 4413339 7.19930 4418676 I1X_VS_X 0.000E-03 0.172E-06 2.298E-06 7.20000 7.19895 4413341 7.19925 4418677 7.19895 4413341 7.19925 4418677 I1X_VS_X 0.000E-03 0.119E-06 1.581E-06 7.20000 7.19890 4413342 7.19920 4418678 7.19890 4413342 7.19920 4418678 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -0.388E-06 -5.169E-06 7.50000 7.50010 4407318 7.50005 4412661 7.50020 4407316 7.50005 4412661