SLAC Magnetic Measurements Date: 04-12-2019 Time: 10:45:37 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 22 Measurement Type: Long Coil Scans Operator: YL Comment: tuning; round 3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_X -0.000E-03 -0.216E-06 -10.372E-06 10.00000 10.00000 4358074 9.99995 4358195 9.99990 4358076 10.00000 4358194 I2X_VS_X -0.000E-03 -0.445E-06 -21.379E-06 10.00000 9.99990 4358076 9.99995 4358195 9.99990 4358076 9.99995 4358195 I2X_VS_X -0.000E-03 -0.507E-06 -24.389E-06 10.00000 9.99980 4358078 10.00000 4358194 9.99985 4358077 9.99995 4358195