SLAC Magnetic Measurements Date: 10-16-2019 Time: 12:20:52 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_028 DATASET Number: 1 Tuning Stage: Tuning Run Number: 7 Measurement Type: Long Coil Scans Operator: YL Comment: Tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 -0.441E-06 8.022E-06 9.00000 9.00010 4.50370 9.00025 4.50330 9.00010 4.50370 9.00025 4.50340