SLAC Magnetic Measurements Date: 09-30-2019 Time: 09:23:39 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_027 DATASET Number: 1 Tuning Stage: Tuning Run Number: 1 Measurement Type: PM Center Operator: YL Comment: Fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000938 -0.033324 0.516355 UPM 2 0.000427 -0.027086 1.361953 DPM 3 0.000340 -0.026891 5.046695 DRM 4 0.000169 -0.032918 5.836088 UPM 2 0.000426 -0.027082 1.361957 DPM 3 0.000338 -0.026897 5.046714 DRM 4 0.000169 -0.032919 5.836085 URM 1 0.000939 -0.033338 0.516381