SLAC Magnetic Measurements Date: 08-30-2019 Time: 16:51:43 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_024 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: PM Center Operator: BP Comment: Fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- DPM 3 0.000028 -0.026552 5.047113 DRM 4 0.000069 -0.032899 5.836468 DRM 4 0.000069 -0.032904 5.836462 DPM 3 0.000027 -0.026555 5.047091 UPM 2 0.000429 -0.026771 1.362626 URM 1 0.000841 -0.033319 0.516873