SLAC Magnetic Measurements Date: 03-01-2019 Time: 13:04:31 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_019 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: VV Comment: All integrals at 9mm gap Nom Gap Position Y I1X I2X I1Y I2Y --------------------------------------------------------------------------- 9.00000 0.000E-03 1.298E-06 0.000E-06 26.316E-06 0.000E-06 9.00000 0.000E-03 1.414E-06 0.000E-06 24.504E-06 0.000E-06 9.00000 0.000E-03 1.344E-06 0.000E-06 25.728E-06 0.000E-06