SLAC Magnetic Measurements Date: 05-25-2019 Time: 07:53:09 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_018 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: VV Comment: initial check Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 0.000E-06 0.000E-06 7.20000 7.19435 3.60030 7.17025 3.59020 7.19430 3.60040 7.17025 3.59020 I1Y_VS_Y 0.000E-03 0.010E-06 0.219E-06 7.20000 7.19415 3.60020 7.17010 3.59010 7.19415 3.60020 7.17005 3.59010 I1Y_VS_Y 0.000E-03 0.489E-06 10.862E-06 7.20000 7.19405 3.60020 7.16995 3.59000 7.19410 3.60020 7.16995 3.59000 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_Y 0.000E-03 1.577E-06 126.658E-06 7.20000 7.19395 3.60020 7.16985 3.59000 7.19395 3.60020 7.16985 3.59000 I2Y_VS_Y 0.000E-03 -1.472E-06 -118.242E-06 7.20000 7.19385 3.60010 7.16975 3.59000 7.19385 3.60010 7.16975 3.59000 I2Y_VS_Y 0.000E-03 -0.579E-06 -46.476E-06 7.20000 7.19375 3.60000 7.16970 3.58990 7.19380 3.60010 7.16970 3.58990 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_Y 0.000E-03 -5.726E-06 127.217E-06 7.20000 7.19370 3.60000 7.16965 3.58980 7.19370 3.60010 7.16960 3.58980