SLAC Magnetic Measurements Date: 10-07-2021 Time: 16:13:28 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_011 DATASET Number: 4 Tuning Stage: Tuning Run Number: 1 Measurement Type: PM Center Operator: YL Comment: coil ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000323 -0.033536 0.513455