SLAC Magnetic Measurements Date: 06-24-2019 Time: 10:33:17 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_005 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: PM Center Operator: VV Comment: fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000977 -0.033293 0.516090 UPM 2 0.000344 -0.025506 1.361974 DPM 3 0.000410 -0.025465 5.046548 DRM 4 0.000211 -0.032879 5.835507 UPM 2 0.000344 -0.025508 1.361891 DPM 3 0.000412 -0.025472 5.046553 DRM 4 0.000212 -0.032888 5.835520 URM 1 0.000978 -0.033311 0.516098