SLAC Magnetic Measurements Date: 12-10-2018 Time: 08:37:26 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_001 DATASET Number: 1 Tuning Stage: Tuning Run Number: 8 Measurement Type: PM Center Operator: VV Comment: fiducialization; Measure US & DS RMs ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000912 -0.033269 0.515937 URM 1 0.000913 -0.033274 0.515946 UPM 2 0.000531 -0.024822 1.353127 UPM 2 0.000532 -0.024827 1.353150 DPM 3 0.000540 -0.024842 5.038034 DPM 3 0.000540 -0.024834 5.038042 DRM 4 0.000922 -0.013382 5.834373 DRM 4 0.000922 -0.013378 5.834383