SLAC Magnetic Measurements Date: 05-30-2017 Time: 16:55:06 Project: LCLS-II Magnet Type: Solenoid Magnet Name: SOL1 Serial Number: Run Number: 8 Measurement Device: LS460 Operator: sda Comment: SOL1 tripped at 10 A, then 1 standardize cycle. Bz vs current. Compare with run 6 Standardization for Main: 1 cycles from -10.0 A to 10.0 A to -10.0 A Test Currents for Main (A): 0.00 5.00 10.00 5.00 0.00 -5.00 -10.00 -5.00 0.00 5.00 10.00 5.00 0.00 -5.00 -10.00 -5.00 0.00 5.00 10.00 5.00 0.00 -5.00 -10.00 -5.00 0.00 5.00 10.00 5.00 0.00 -5.00 -10.00 -5.00 0.00 16:56:29 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 16:56:32 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:56:32 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 16:57:06 Move Stages, x_position = 0.000000 m, y_position = 0.150000 m 16:58:18 3 Axis Hall Probe Zeroed 16:58:51 3 Axis Hall Probe Type Being Used, type = LS460 16:59:26 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:59:31 Magnet Current for Main, Imag = 0.0002 A Vtrans = 0.000019 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:32 Magnet Current for Main, Imag = 0.0002 A Vtrans = 0.000018 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:33 Magnet Current for Main, Imag = 0.0002 A Vtrans = 0.000019 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:33 Magnet Current for Main, Imag = 0.0002 A Vtrans = 0.000019 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:34 Magnet Avgerage Current Measurement for Main : Imag = 0.0002 +- 0.0000 A 16:59:49 Initial Zero Current Measurement for Main, Imag_zero = 0.000223092 A 16:59:50 3 Axis Hall Probe Range Set, range = 1 16:59:50 Magnet system Main current ramping to 10.0000 A... 17:00:05 Magnet system Main current ramping to -10.0000 A... 17:00:25 Magnet system Main current ramping to 0.0000 A... 17:00:43 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:00:46 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:00:46 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:00:47 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:00:48 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000049 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:00:49 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:00:49 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:00:49 3 Axis Hall Probe Field Measurement, Bx = 0.000000, By = 0.000000, Bz = 0.000020 T 17:00:49 Magnet system Main current ramping to 5.0000 A... 17:01:04 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:01:06 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:01:07 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416529 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:08 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416529 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:09 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416529 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:09 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416529 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:09 Magnet Avgerage Current Measurement for Main : Imag = 4.9981 +- 0.0000 A 17:01:10 3 Axis Hall Probe Field Measurement, Bx = -0.000440, By = 0.000120, Bz = -0.047010 T 17:01:10 Magnet system Main current ramping to 10.0000 A... 17:01:25 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:01:28 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:01:28 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833391 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:29 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833391 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:30 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833389 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:31 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833390 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:31 Magnet Avgerage Current Measurement for Main : Imag = 10.0005 +- 0.0000 A 17:01:31 3 Axis Hall Probe Field Measurement, Bx = -0.000910, By = 0.000230, Bz = -0.094020 T 17:01:31 Magnet system Main current ramping to 5.0000 A... 17:01:46 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:01:49 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:01:49 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:50 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:51 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:52 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416535 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:01:52 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:01:52 3 Axis Hall Probe Field Measurement, Bx = -0.000450, By = 0.000120, Bz = -0.047030 T 17:01:52 Magnet system Main current ramping to 0.0000 A... 17:02:08 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:02:10 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:02:10 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:11 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:12 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:13 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:13 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:02:13 3 Axis Hall Probe Field Measurement, Bx = 0.000010, By = 0.000000, Bz = -0.000020 T 17:02:13 Magnet system Main current ramping to -5.0000 A... 17:02:28 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:02:30 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:02:31 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:32 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:33 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:33 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416872 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:33 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:02:33 3 Axis Hall Probe Field Measurement, Bx = 0.000440, By = -0.000120, Bz = 0.047000 T 17:02:34 Magnet system Main current ramping to -10.0000 A... 17:02:49 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:02:51 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:02:52 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833920 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:53 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833920 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:54 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833921 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:55 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833922 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:02:55 Magnet Avgerage Current Measurement for Main : Imag = -10.0073 +- 0.0000 A 17:02:55 3 Axis Hall Probe Field Measurement, Bx = 0.000900, By = -0.000240, Bz = 0.094040 T 17:02:56 Magnet system Main current ramping to -5.0000 A... 17:03:11 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:03:14 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:03:15 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416877 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:16 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416876 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:17 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416877 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:17 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416876 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:18 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:03:18 3 Axis Hall Probe Field Measurement, Bx = 0.000450, By = -0.000110, Bz = 0.047020 T 17:03:18 Magnet system Main current ramping to 0.0000 A... 17:03:34 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:03:37 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:03:38 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:38 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:39 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:40 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000048 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:03:40 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:03:40 3 Axis Hall Probe Field Measurement, Bx = 0.000000, By = 0.000000, Bz = 0.000020 T 17:03:41 Magnet system Main current ramping to 5.0000 A... 17:03:56 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:03:59 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:04:00 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416530 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:00 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:01 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:02 Magnet Current for Main, Imag = 4.9981 A Vtrans = 0.416531 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:03 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:04:03 3 Axis Hall Probe Field Measurement, Bx = -0.000440, By = 0.000120, Bz = -0.047010 T 17:04:03 Magnet system Main current ramping to 10.0000 A... 17:04:19 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:04:21 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:04:22 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833394 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:23 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833391 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:24 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:24 Magnet Current for Main, Imag = 10.0006 A Vtrans = 0.833399 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:24 Magnet Avgerage Current Measurement for Main : Imag = 10.0005 +- 0.0000 A 17:04:25 3 Axis Hall Probe Field Measurement, Bx = -0.000900, By = 0.000230, Bz = -0.094010 T 17:04:25 Magnet system Main current ramping to 5.0000 A... 17:04:41 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:04:43 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:04:44 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:45 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:46 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416537 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:47 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416539 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:04:47 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:04:47 3 Axis Hall Probe Field Measurement, Bx = -0.000450, By = 0.000120, Bz = -0.047030 T 17:04:48 Magnet system Main current ramping to 0.0000 A... 17:05:04 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:05:06 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:05:07 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000045 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:08 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000045 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:09 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:10 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:10 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:05:10 3 Axis Hall Probe Field Measurement, Bx = 0.000010, By = 0.000000, Bz = -0.000030 T 17:05:10 Magnet system Main current ramping to -5.0000 A... 17:05:26 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:05:28 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:05:29 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416872 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:30 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:31 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416872 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:32 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416872 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:32 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:05:32 3 Axis Hall Probe Field Measurement, Bx = 0.000450, By = -0.000120, Bz = 0.047000 T 17:05:33 Magnet system Main current ramping to -10.0000 A... 17:05:48 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:05:51 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:05:52 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833921 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:53 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833921 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:54 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833922 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:54 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833922 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:05:55 Magnet Avgerage Current Measurement for Main : Imag = -10.0073 +- 0.0000 A 17:05:55 3 Axis Hall Probe Field Measurement, Bx = 0.000890, By = -0.000240, Bz = 0.094040 T 17:05:55 Magnet system Main current ramping to -5.0000 A... 17:06:11 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:06:13 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:06:14 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416877 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:15 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416875 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:16 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416877 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:17 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416876 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:17 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:06:17 3 Axis Hall Probe Field Measurement, Bx = 0.000440, By = -0.000120, Bz = 0.047030 T 17:06:17 Magnet system Main current ramping to 0.0000 A... 17:06:32 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:06:35 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:06:36 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:37 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000044 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:38 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:39 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000045 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:39 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:06:39 3 Axis Hall Probe Field Measurement, Bx = -0.000010, By = 0.000000, Bz = 0.000020 T 17:06:40 Magnet system Main current ramping to 5.0000 A... 17:06:55 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:06:57 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:06:58 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416531 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:06:59 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:00 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:01 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:01 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:07:01 3 Axis Hall Probe Field Measurement, Bx = -0.000450, By = 0.000120, Bz = -0.047010 T 17:07:02 Magnet system Main current ramping to 10.0000 A... 17:07:17 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:07:20 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:07:21 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833393 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:22 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833392 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:23 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833394 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:24 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833395 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:24 Magnet Avgerage Current Measurement for Main : Imag = 10.0005 +- 0.0000 A 17:07:24 3 Axis Hall Probe Field Measurement, Bx = -0.000910, By = 0.000240, Bz = -0.094000 T 17:07:25 Magnet system Main current ramping to 5.0000 A... 17:07:41 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:07:43 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:07:44 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416539 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:45 Magnet Current for Main, Imag = 4.9983 A Vtrans = 0.416540 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:46 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416538 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:47 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416539 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:07:47 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:07:47 3 Axis Hall Probe Field Measurement, Bx = -0.000450, By = 0.000120, Bz = -0.047030 T 17:07:47 Magnet system Main current ramping to 0.0000 A... 17:08:03 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:08:05 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:08:06 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:07 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:08 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:09 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:09 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:08:09 3 Axis Hall Probe Field Measurement, Bx = 0.000010, By = 0.000000, Bz = -0.000020 T 17:08:09 Magnet system Main current ramping to -5.0000 A... 17:08:24 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:08:27 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:08:27 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:28 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416874 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:29 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416874 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:30 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416873 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:31 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:08:31 3 Axis Hall Probe Field Measurement, Bx = 0.000450, By = -0.000120, Bz = 0.047000 T 17:08:31 Magnet system Main current ramping to -10.0000 A... 17:08:47 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:08:50 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:08:50 Magnet Current for Main, Imag = -10.0072 A Vtrans = -0.833918 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:51 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833919 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:52 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833921 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:53 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833920 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:08:53 Magnet Avgerage Current Measurement for Main : Imag = -10.0073 +- 0.0000 A 17:08:53 3 Axis Hall Probe Field Measurement, Bx = 0.000890, By = -0.000240, Bz = 0.094020 T 17:08:54 Magnet system Main current ramping to -5.0000 A... 17:09:10 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:09:12 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:09:13 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416876 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:14 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416876 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:14 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416877 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:15 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416878 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:15 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:09:15 3 Axis Hall Probe Field Measurement, Bx = 0.000440, By = -0.000120, Bz = 0.047040 T 17:09:15 Magnet system Main current ramping to 0.0000 A... 17:09:31 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:09:33 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:09:34 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000045 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:35 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:35 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:36 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:36 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:09:36 3 Axis Hall Probe Field Measurement, Bx = 0.000000, By = 0.000010, Bz = 0.000020 T 17:09:36 Magnet system Main current ramping to 5.0000 A... 17:09:52 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:09:54 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:09:55 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:56 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416531 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:57 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416532 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:57 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416531 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:09:57 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:09:58 3 Axis Hall Probe Field Measurement, Bx = -0.000440, By = 0.000120, Bz = -0.047000 T 17:09:58 Magnet system Main current ramping to 10.0000 A... 17:10:13 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:10:16 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:10:16 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833394 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:17 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833394 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:18 Magnet Current for Main, Imag = 10.0005 A Vtrans = 0.833394 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:19 Magnet Current for Main, Imag = 10.0006 A Vtrans = 0.833401 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:19 Magnet Avgerage Current Measurement for Main : Imag = 10.0005 +- 0.0000 A 17:10:19 3 Axis Hall Probe Field Measurement, Bx = -0.000900, By = 0.000230, Bz = -0.094000 T 17:10:19 Magnet system Main current ramping to 5.0000 A... 17:10:34 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:10:36 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:10:37 Magnet Current for Main, Imag = 4.9983 A Vtrans = 0.416540 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:38 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416539 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:38 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416538 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:39 Magnet Current for Main, Imag = 4.9982 A Vtrans = 0.416539 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:39 Magnet Avgerage Current Measurement for Main : Imag = 4.9982 +- 0.0000 A 17:10:39 3 Axis Hall Probe Field Measurement, Bx = -0.000440, By = 0.000130, Bz = -0.047030 T 17:10:39 Magnet system Main current ramping to 0.0000 A... 17:10:55 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:10:57 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:10:58 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:58 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:10:59 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:00 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000047 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:00 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:11:00 3 Axis Hall Probe Field Measurement, Bx = 0.000010, By = 0.000000, Bz = -0.000020 T 17:11:00 Magnet system Main current ramping to -5.0000 A... 17:11:16 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:11:18 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:11:19 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416874 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:20 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416874 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:20 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416874 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:21 Magnet Current for Main, Imag = -5.0027 A Vtrans = -0.416875 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:21 Magnet Avgerage Current Measurement for Main : Imag = -5.0027 +- 0.0000 A 17:11:21 3 Axis Hall Probe Field Measurement, Bx = 0.000450, By = -0.000120, Bz = 0.047000 T 17:11:21 Magnet system Main current ramping to -10.0000 A... 17:11:37 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:11:39 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:11:40 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833922 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:41 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833922 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:42 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833923 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:42 Magnet Current for Main, Imag = -10.0073 A Vtrans = -0.833923 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:11:42 Magnet Avgerage Current Measurement for Main : Imag = -10.0073 +- 0.0000 A 17:11:43 3 Axis Hall Probe Field Measurement, Bx = 0.000890, By = -0.000230, Bz = 0.094020 T 17:11:43 Magnet system Main current ramping to -5.0000 A... 17:11:58 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:12:01 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:12:01 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416878 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:02 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416879 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:03 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416878 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:04 Magnet Current for Main, Imag = -5.0028 A Vtrans = -0.416878 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:04 Magnet Avgerage Current Measurement for Main : Imag = -5.0028 +- 0.0000 A 17:12:04 3 Axis Hall Probe Field Measurement, Bx = 0.000440, By = -0.000110, Bz = 0.047030 T 17:12:04 Magnet system Main current ramping to 0.0000 A... 17:12:19 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:12:22 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 17:12:22 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:23 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:24 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:25 Magnet Current for Main, Imag = -0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000223 A 17:12:25 Magnet Avgerage Current Measurement for Main : Imag = -0.0008 +- 0.0000 A 17:12:25 3 Axis Hall Probe Field Measurement, Bx = -0.000010, By = 0.000000, Bz = 0.000030 T 17:12:28 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:12:28 Magnet system Main current ramping to 0.0000 A...