SLAC Magnetic Measurements Date: 05-28-2026 Time: 15:38:08 Project: LCLS-II Magnet Type: Quad Magnet Name: 4213 Serial Number: Run Number: 4 Measurement Device: 1DQSB26 Operator: sda Comment: Integrated gradient for coil calibration after 1/2 hr warmup at 165 amps Standardization for MAIN: 3 cycles from 0.0 A to 165.0 A to 0.0 A Test Currents for MAIN (A): 165.00 Integrated Gradient (Quadrupole) MAIN +/- sigma BL sigBL TF sigTF THsp sigTHsp (A) (T) (T/A) (deg) ------------+---------- -----------+----------- ------------+------------ -----------+--------- 165.0198 0.0062 5.204318 0.000107 0.031538 0.000002 44.6855 0.0001 165.0195 0.0041 5.204555 0.000025 0.031539 0.000001 44.6855 0.0001 165.0235 0.0049 5.204626 0.000014 0.031539 0.000001 44.6855 0.0000