Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0944 262.7591 -0.2586 1.3007 -2.9515 7 333.0909 262.7606 -0.2659 1.1412 -3.2097 Mean 333.0926 262.7598 -0.2623 1.2209 -3.0806 Std 0.0025 0.0011 0.0052 0.1128 0.1825 Error 0.00373 0.00168 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -4.7269 5.3773 1.8277 27.3768 11.0589 5.1492 7 -13.2070 5.4373 4.9777 28.8868 7.4945 6.7243 Mean -8.9669 5.4073 3.4027 28.1318 9.2767 5.9367 Std 5.9963 0.0425 2.2274 1.0677 2.5204 1.1138