Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0864 262.7585 -1.3132 -1.0327 4.6114 7 333.0891 262.7596 -1.3136 -1.0893 4.3257 Mean 333.0878 262.7591 -1.3134 -1.0610 4.4685 Std 0.0019 0.0008 0.0003 0.0400 0.2021 Error 0.00389 0.00165 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -5.7576 4.8278 1.2978 12.0761 3.0141 4.6087 7 -3.4876 5.1979 3.1278 15.3161 5.7617 5.6948 Mean -4.6226 5.0128 2.2128 13.6961 4.3879 5.1517 Std 1.6051 0.2617 1.2940 2.2911 1.9428 0.7680