Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0845 263.5623 0.7786 0.3714 -0.3614 7 333.0855 263.5622 0.7840 0.6006 -0.4612 Mean 333.0850 263.5622 0.7813 0.4860 -0.4113 Std 0.0007 0.0001 0.0038 0.1621 0.0706 Error 0.00266 0.00105 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -6.5675 940.4276 668.2378 8.9861 1.0833 808.4079 7 -5.8875 942.5077 665.7278 10.4062 2.1253 808.2835 Mean -6.2275 941.4676 666.9828 9.6962 1.6043 808.3457 Std 0.4809 1.4709 1.7748 1.0041 0.7368 0.0879