Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 10 333.1768 262.5421 -0.4195 0.5149 2.2324 9 333.1736 262.5406 -0.4150 0.4403 1.8329 Mean 333.1752 262.5413 -0.4172 0.4776 2.0327 Std 0.0022 0.0011 0.0032 0.0527 0.2825 Error 0.000866 0.00133 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 10 -2.9800 -3.1911 -10.2821 7.7557 93.3477 -211.7814 9 -6.3600 -5.9812 -10.4621 4.7257 90.2062 -213.3034 Mean -4.6700 -4.5862 -10.3721 6.2407 91.7770 -212.5424 Std 2.3900 1.9729 0.1273 2.1426 2.2214 1.0762