SLAC Magnetic Measurements Date: 07-18-2019 Time: 12:32:43 Project: LCLS-II Device Type: Phase Shifter Data Type: Serial Number: HXPS_16329 Run Number: 21 Measurement Type: Stretched Wire Operator: VV Comment: testing connections Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 1254.750E-06 57.811E-06 10.00000 9.99925 20440183 0.00000 0 9.99925 20440183 0.00000 0