SLAC Magnetic Measurements Date: 11-27-2018 Time: 16:39:20 Project: LCLS-II Device Type: Phase Shifter Data Type: Serial Number: HXPS_16307 Run Number: 23 Measurement Type: Stretched Wire Operator: VV Comment: mag_axis_X=+0.089 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -626.074E-06 -28.835E-06 10.00000 9.99875 17050970 0.00000 0 9.99800 17050975 0.00000 0 I1Y_VS_X 0.000E-03 86.572E-06 3.988E-06 10.00000 9.99700 17050975 0.00000 0 9.99775 17050974 0.00000 0 I1Y_VS_X 0.000E-03 531.261E-06 24.471E-06 10.00000 9.99750 17050975 0.00000 0 9.99775 17050975 0.00000 0 I1Y_VS_X 0.000E-03 2000.471E-06 92.151E-06 10.00000 9.99725 17050974 0.00000 0 9.99775 17050973 0.00000 0 I1Y_VS_X 0.000E-03 -189.250E-06 -8.718E-06 10.00000 9.99625 17050976 0.00000 0 9.99850 17050970 0.00000 0