UFx.py version 1.3 from 07/06/2018
Page 1 of 1
Created by user vjeran on 07/06/2018 17:19:00
SLAC Moving Wire Magnetic Measurement Summary
| Magnet ID : | Calibration |
| Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_downstream\Final Results\Stretched Wire |
| Date : | 06-29-2018 |
| Time : | 12:34:58 - 13:39:19 |
| Operator : | VV |
| Project : | LCLS-II |
| Device Type : | Phase Shifter |
| Run Number : | 1 |
| Data Type : | |
| Run Comment : | 126 Gauss*cm magnet, +By, downstream pos |
| gap | I1Y | I2Y | I1X | I2X |
|
- |
111.9 2.0 (5) |
5.5 1.8 (5) |
6.1 4.3 (5) |
2.5 2.0 (5) |
| integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
| I1Y |
- |
110.6 5.7 (3) |
107.9 1.8 (3) |
115.3 1.7 (3) |
103.5 3.3 (3) |
108.9 3.0 (3) |
| I2Y |
- |
6.3 1.5 (3) |
5.8 1.1 (3) |
7.3 2.2 (3) |
7.1 1.9 (3) |
6.1 1.0 (3) |
| I1X |
- |
4.2 6.1 (3) |
5.7 2.6 (3) |
5.1 5.5 (3) |
-9.5 21.1 (3) |
2.4 2.8 (3) |
| I2X |
- |
0.8 0.4 (3) |
1.2 0.7 (3) |
-1.4 1.4 (3) |
1.1 0.7 (3) |
-0.7 1.0 (3) |
| integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
| I1Y |
- |
110.4 2.2 (3) |
111.7 9.6 (3) |
106.4 3.0 (3) |
106.3 2.5 (3) |
109.0 3.8 (3) |
| I2Y |
- |
6.7 0.6 (3) |
7.4 2.2 (3) |
6.2 0.5 (3) |
7.3 0.7 (3) |
5.5 1.8 (3) |
| I1X |
- |
3.3 1.3 (3) |
-1.1 1.7 (3) |
3.2 1.9 (3) |
3.6 3.2 (3) |
5.9 1.5 (3) |
| I2X |
- |
1.3 1.9 (3) |
-0.2 0.9 (3) |
-0.2 1.4 (3) |
2.0 1.7 (3) |
-0.4 3.9 (3) |