UFx.py version 1.3 from 07/06/2018
Page 1 of 1
Created by user vjeran on 07/06/2018 17:18:01
SLAC Moving Wire Magnetic Measurement Summary
| Magnet ID : | Calibration |
| Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_center\Final Results\Stretched Wire |
| Date : | 06-29-2018 |
| Time : | 11:12:25 - 12:16:51 |
| Operator : | VV |
| Project : | LCLS-II |
| Device Type : | Phase Shifter |
| Run Number : | 1 |
| Data Type : | |
| Run Comment : | 126 Gauss*cm magnet, +By, center pos |
| gap | I1Y | I2Y | I1X | I2X |
|
- |
107.5 3.7 (5) |
21.8 1.4 (5) |
4.2 2.2 (5) |
1.7 1.9 (5) |
| integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
| I1Y |
- |
102.9 10.2 (3) |
105.4 2.3 (3) |
107.4 2.1 (3) |
109.9 2.6 (3) |
109.5 2.2 (3) |
| I2Y |
- |
21.6 0.2 (3) |
20.9 1.6 (3) |
22.7 1.3 (3) |
22.4 1.1 (3) |
23.1 1.7 (3) |
| I1X |
- |
3.9 2.0 (3) |
6.9 1.5 (3) |
2.6 3.5 (3) |
1.8 3.1 (3) |
3.0 3.4 (3) |
| I2X |
- |
1.5 1.2 (3) |
0.5 0.5 (3) |
-0.0 0.9 (3) |
1.1 1.3 (3) |
1.0 1.3 (3) |
| integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
| I1Y |
- |
112.0 6.3 (3) |
109.6 0.7 (3) |
107.8 1.5 (3) |
112.8 0.7 (3) |
110.7 1.8 (3) |
| I2Y |
- |
22.2 3.2 (3) |
22.9 3.3 (3) |
22.9 1.5 (3) |
23.5 1.0 (3) |
21.0 0.8 (3) |
| I1X |
- |
2.6 2.9 (3) |
1.1 5.7 (3) |
2.3 4.1 (3) |
-0.5 2.4 (3) |
4.6 0.5 (3) |
| I2X |
- |
-7.5 9.2 (3) |
0.8 0.3 (3) |
1.0 0.7 (3) |
1.8 2.2 (3) |
-0.5 1.9 (3) |