SLAC Moving Wire Magnetic Measurement Summary
| Magnet ID : | Calibration |
| Directory : | S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+By_center\Final Results\Stretched Wire |
| Date : | 06-29-2018 |
| Time : | 11:12:25 - 12:16:51 |
| Operator : | VV |
| Project : | LCLS-II |
| Device Type : | Phase Shifter |
| Run Number : | 1 |
| Data Type : | |
| Run Comment : | 126 Gauss*cm magnet, +By, center pos |
| gap | I1Y | I2Y | I1X | I2X |
|
- |
109.9 0.3 (5) |
22.0 0.3 (5) |
3.5 0.4 (5) |
1.0 0.3 (5) |
| integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
| I1Y |
- |
105.1 5.8 (3) |
108.8 0.9 (3) |
105.3 6.1 (3) |
108.8 0.9 (3) |
108.5 0.7 (3) |
| I2Y |
- |
22.0 0.3 (3) |
21.7 0.4 (3) |
21.7 0.2 (3) |
21.9 0.4 (3) |
21.8 0.3 (3) |
| I1X |
- |
4.3 0.7 (3) |
4.0 0.9 (3) |
4.5 0.8 (3) |
3.5 0.6 (3) |
3.8 0.9 (3) |
| I2X |
- |
1.0 0.2 (3) |
0.8 0.2 (3) |
1.0 0.3 (3) |
0.9 0.1 (3) |
0.9 0.3 (3) |
| integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
| I1Y |
- |
106.2 7.5 (3) |
109.1 0.4 (3) |
104.9 6.1 (3) |
109.5 0.4 (3) |
105.3 6.4 (3) |
| I2Y |
- |
21.4 1.5 (3) |
21.9 0.1 (3) |
22.2 0.2 (3) |
21.8 0.2 (3) |
22.0 0.2 (3) |
| I1X |
- |
3.5 0.2 (3) |
0.8 0.4 (3) |
2.4 1.7 (3) |
1.7 1.2 (3) |
1.5 1.5 (3) |
| I2X |
- |
1.3 0.3 (2) |
0.3 0.1 (3) |
1.0 0.6 (3) |
0.4 0.1 (3) |
0.6 0.4 (3) |