Magnet ID :     Calibration
Directory : S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+Bx_upstream\Final Results\Stretched Wire
   
Date : 06-29-2018
Time : 16:22:31 - 17:26:51
Operator : VV
   
Project : LCLS-II
Device Type : Phase Shifter
Run Number : 1
Data Type :
Run Comment : 126 Gauss*cm magnet rotated, +Bx, upstream pos
   
gap I1Y I2Y I1X I2X
-
-8.8 4.3 (5)
-1.8 1.1 (5)
116.9 3.6 (5)
41.2 1.6 (5)

integral gap -02.00;+00.00 -01.00;+00.00 +00.00;+00.00 +01.00;+00.00 +02.00;+00.00
I1Y -
-14.7 4.5 (3)
-13.3 3.3 (3)
-14.6 4.4 (3)
-12.5 4.6 (3)
-14.8 4.4 (3)
I2Y -
-3.5 2.0 (3)
-2.1 2.5 (3)
0.7 4.1 (3)
-3.4 2.5 (3)
-4.2 3.0 (3)
I1X -
119.2 3.6 (3)
120.1 1.5 (3)
116.3 3.8 (3)
120.4 6.2 (3)
119.2 3.5 (3)
I2X -
40.2 1.3 (3)
39.4 3.2 (3)
40.1 0.8 (3)
40.1 2.7 (3)
40.3 0.8 (3)

integral gap +00.00;-02.00 +00.00;-01.00 +00.00;+00.00 +00.00;+01.00 +00.00;+02.00
I1Y -
-8.4 4.2 (3)
-11.0 7.0 (3)
-13.7 3.5 (3)
-8.3 2.1 (3)
-12.9 2.3 (3)
I2Y -
-3.4 2.6 (3)
-3.1 1.7 (3)
-2.9 0.7 (3)
-2.7 2.2 (3)
-5.6 0.8 (3)
I1X -
121.3 5.2 (3)
115.7 4.7 (3)
119.6 3.4 (3)
117.2 2.3 (3)
119.7 5.6 (3)
I2X -
41.7 1.4 (3)
39.9 1.3 (3)
40.2 0.9 (3)
38.4 1.9 (3)
39.9 1.4 (3)

   
Magnet ID :     Calibration
Directory : S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+Bx_upstream\Final Results\Stretched Wire