UFx.py version 2.1 from 10/19/2018
Page 1 of 2
Created by user vjeran on 10/19/2018 16:41:29
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
| Magnet ID : | Background |
| Directory : | S:\magdata\LCLS-II\Phase Shifter\Background\Stretched Wire HXR\DATASET0001\Final Results\Stretched Wire |
| Date : | 08-29-2018 |
| Time : | 12:06:08 - 13:15:02 |
| Operator : | VV |
| Project : | LCLS-II |
| Device Type : | Phase Shifter |
| Run Number : | 1 |
| Data Type : | |
| Run Comment : | HXR measurement situation |
| gap | I1Y | I2Y | I1X | I2X |
|
- |
-11.1 4.9 (5) |
-2.3 1.8 (5) |
16.3 3.3 (5) |
4.3 5.3 (5) |
| integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
| I1Y |
- |
-11.8 1.9 (3) |
-0.5 4.6 (3) |
-11.3 12.1 (3) |
2.2 2.8 (3) |
-12.0 1.0 (3) |
| I2Y |
- |
-2.3 2.8 (3) |
-0.1 1.1 (3) |
-2.4 0.4 (3) |
-1.8 1.9 (3) |
-1.1 0.3 (3) |
| I1X |
- |
13.9 2.6 (3) |
7.8 1.6 (3) |
8.6 2.8 (3) |
9.9 11.2 (3) |
12.0 1.2 (3) |
| I2X |
- |
1.4 4.2 (3) |
0.8 1.4 (3) |
1.0 0.7 (3) |
2.8 2.2 (3) |
2.8 0.6 (3) |
| integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
| I1Y |
- |
-10.8 2.3 (3) |
-8.4 2.4 (3) |
-9.0 4.7 (3) |
-6.5 4.8 (3) |
-11.7 2.1 (3) |
| I2Y |
- |
-2.5 1.2 (3) |
-2.4 2.2 (3) |
-3.3 1.5 (3) |
-5.0 5.2 (3) |
-1.8 2.4 (3) |
| I1X |
- |
12.6 3.3 (3) |
7.4 4.0 (3) |
10.8 2.9 (3) |
7.5 4.7 (3) |
12.5 4.9 (3) |
| I2X |
- |
1.5 1.6 (3) |
0.8 0.9 (3) |
1.5 2.4 (3) |
1.9 2.2 (3) |
4.1 2.6 (3) |
UFx.py version 2.1 from 10/19/2018
Page 2 of 2
Created by user vjeran on 10/19/2018 16:41:29
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
| Magnet ID : | Background |
| Directory : | S:\magdata\LCLS-II\Phase Shifter\Background\Stretched Wire HXR\DATASET0001\Final Results\Stretched Wire |