-8.0e-5 is temperature coefficient Zack calculated for the encoder arm. This is seperate from the manget coefficient (-1e-3) which is taken out in the SXU EPICS software. Tried using this standrad -8.0e-5 factor and it didn't work, seems each SXU is different, though interestingly the average correction factor for all of the SXUs are 8.6318e-05 for plus gap move and 7.4739e-05 for the minus gap move. The average of the plus and minus move is 8.0528e-05! The plots made using a standard Cell_GI.Calib_correction_factor_plus/minus = -8.0e-5 in Matlab program SXU_ISRDD_Cell_Summary are in this directory. For more info see: LCLS-TN 20-1 "Temperature Dependance of LCLS-II Undulators and Phase Shifters"