SLAC Magnetic Measurements Date: 09-27-2022 Time: 14:33:46 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: Background_off_axis Center position: X0=0.001000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -7.853E-06 -82.166E-06 75.00000 75.00015 0 75.00015 0 75.00015 0 75.00015 0 1 -8.058E-06 -85.091E-06 75.00000 75.00020 0 75.00010 0 75.00015 0 75.00015 0 2 -5.645E-06 -80.626E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00010 0 3 -5.793E-06 -82.742E-06 75.00000 75.00015 0 75.00010 0 75.00010 0 75.00010 0 4 -5.751E-06 -82.141E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00010 0