SLAC Magnetic Measurements Date: 09-29-2022 Time: 12:02:58 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 66 Measurement Type: Long Coil Scans Operator: YL Comment: 2H; Bx field; Aisle - AW, Bench -TW Center position: X0=0.000000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -7.236E-06 -103.354E-06 75.00000 75.00010 0 75.00010 0 75.00010 0 75.00005 0 1 -7.000E-06 -99.977E-06 75.00000 75.00010 0 75.00005 0 75.00010 0 75.00010 0 2 -7.268E-06 -103.812E-06 75.00000 75.00010 0 75.00010 0 75.00015 0 75.00005 0 3 -6.939E-06 -99.106E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00005 0 4 -7.003E-06 -100.022E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00010 0