SLAC Magnetic Measurements Date: 09-27-2022 Time: 18:20:26 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -1.483E-06 -21.178E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00015 0 1 -1.599E-06 -22.844E-06 75.00000 75.00010 0 75.00010 0 75.00010 0 75.00010 0 2 -1.693E-06 -24.185E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00015 0 3 -1.657E-06 -23.663E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00015 0 4 -1.724E-06 -24.618E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00015 0