SLAC Magnetic Measurements Date: 09-27-2022 Time: 17:29:03 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=25.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.578E-06 8.255E-06 25.00000 25.00010 0 25.00000 0 25.00010 0 25.00005 0 1 0.633E-06 9.042E-06 25.00000 25.00020 0 25.00005 0 25.00020 0 25.00005 0 2 0.656E-06 9.363E-06 25.00000 25.00020 0 25.00010 0 25.00020 0 25.00005 0 3 0.508E-06 7.250E-06 25.00000 25.00025 0 25.00005 0 25.00030 0 25.00005 0 4 0.499E-06 7.134E-06 25.00000 25.00030 0 25.00005 0 25.00030 0 25.00010 0