SLAC Magnetic Measurements Date: 09-27-2022 Time: 16:55:39 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=12.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.185E-06 16.923E-06 12.00000 12.00035 0 12.00010 0 12.00035 0 12.00010 0 1 1.235E-06 17.634E-06 12.00000 12.00035 0 12.00015 0 12.00035 0 12.00015 0 2 1.379E-06 19.694E-06 12.00000 12.00035 0 12.00015 0 12.00040 0 12.00010 0 3 1.214E-06 17.342E-06 12.00000 12.00035 0 12.00020 0 12.00040 0 12.00015 0 4 1.123E-06 16.033E-06 12.00000 12.00035 0 12.00015 0 12.00035 0 12.00015 0