SLAC Magnetic Measurements Date: 09-27-2022 Time: 16:40:33 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.228E-06 17.543E-06 10.00000 10.00045 0 10.00035 0 10.00045 0 10.00035 0 1 1.230E-06 17.573E-06 10.00000 10.00045 0 10.00040 0 10.00040 0 10.00040 0 2 1.009E-06 14.414E-06 10.00000 10.00045 0 10.00040 0 10.00045 0 10.00035 0 3 1.245E-06 17.784E-06 10.00000 10.00050 0 10.00040 0 10.00045 0 10.00040 0 4 1.141E-06 16.297E-06 10.00000 10.00045 0 10.00045 0 10.00045 0 10.00040 0