SLAC Magnetic Measurements Date: 09-27-2022 Time: 15:40:17 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=7.20 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.533E-06 7.612E-06 7.20000 7.19690 0 7.19815 0 7.19695 0 7.19810 0 1 0.502E-06 7.165E-06 7.20000 7.19690 0 7.19815 0 7.19690 0 7.19815 0 2 0.587E-06 8.384E-06 7.20000 7.19690 0 7.19810 0 7.19685 0 7.19815 0 3 0.098E-06 1.399E-06 7.20000 7.19685 0 7.19810 0 7.19685 0 7.19810 0 4 0.432E-06 6.174E-06 7.20000 7.19685 0 7.19805 0 7.19685 0 7.19805 0