SLAC Magnetic Measurements Date: 09-27-2022 Time: 15:32:37 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=7.20 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -3.062E-06 -43.727E-06 7.20000 7.19730 0 7.19855 0 7.19730 0 7.19855 0 1 -2.991E-06 -42.714E-06 7.20000 7.19725 0 7.19855 0 7.19725 0 7.19855 0 2 -2.864E-06 -40.910E-06 7.20000 7.19720 0 7.19850 0 7.19725 0 7.19850 0 3 -3.013E-06 -43.030E-06 7.20000 7.19720 0 7.19845 0 7.19720 0 7.19845 0 4 -3.005E-06 -42.919E-06 7.20000 7.19720 0 7.19845 0 7.19720 0 7.19845 0