SLAC Magnetic Measurements Date: 10-04-2022 Time: 16:25:58 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=0.000000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -3.946E-06 -56.364E-06 50.00000 50.00015 0 50.00010 0 50.00015 0 50.00005 0 1 -3.871E-06 -55.292E-06 50.00000 50.00015 0 50.00015 0 50.00010 0 50.00015 0 2 -3.978E-06 -56.811E-06 50.00000 50.00010 0 50.00020 0 50.00015 0 50.00015 0 3 -4.029E-06 -57.539E-06 50.00000 50.00015 0 50.00015 0 50.00020 0 50.00010 0 4 -3.855E-06 -55.057E-06 50.00000 50.00020 0 50.00015 0 50.00015 0 50.00015 0