SLAC Magnetic Measurements Date: 10-04-2022 Time: 16:23:46 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -4.641E-06 -66.286E-06 50.00000 50.00000 0 50.00005 0 50.00000 0 50.00010 0 1 -4.742E-06 -67.727E-06 50.00000 50.00005 0 50.00005 0 50.00005 0 50.00010 0 2 -4.680E-06 -66.847E-06 50.00000 50.00005 0 50.00005 0 50.00005 0 50.00010 0 3 -4.595E-06 -65.627E-06 50.00000 50.00010 0 50.00005 0 50.00010 0 50.00010 0 4 -4.451E-06 -63.571E-06 50.00000 50.00010 0 50.00010 0 50.00010 0 50.00015 0