SLAC Magnetic Measurements Date: 10-04-2022 Time: 15:40:40 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=0.002000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.892E-06 12.740E-06 10.00000 10.00030 0 10.00035 0 10.00035 0 10.00030 0 1 0.850E-06 12.135E-06 10.00000 10.00030 0 10.00030 0 10.00035 0 10.00025 0 2 0.967E-06 13.813E-06 10.00000 10.00035 0 10.00030 0 10.00035 0 10.00030 0 3 1.218E-06 17.396E-06 10.00000 10.00035 0 10.00030 0 10.00035 0 10.00025 0 4 0.888E-06 12.683E-06 10.00000 10.00035 0 10.00030 0 10.00035 0 10.00035 0