SLAC Magnetic Measurements Date: 10-04-2022 Time: 15:27:45 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=9.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 2.102E-06 30.016E-06 9.00000 9.00010 0 9.00015 0 9.00015 0 9.00020 0 1 2.204E-06 31.477E-06 9.00000 9.00020 0 9.00025 0 9.00025 0 9.00025 0 2 2.105E-06 30.069E-06 9.00000 9.00025 0 9.00030 0 9.00025 0 9.00030 0 3 2.070E-06 29.572E-06 9.00000 9.00030 0 9.00030 0 9.00030 0 9.00030 0 4 2.153E-06 30.755E-06 9.00000 9.00030 0 9.00035 0 9.00030 0 9.00035 0