SLAC Magnetic Measurements Date: 09-28-2022 Time: 11:07:15 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=15.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.702E-06 24.309E-06 15.00000 15.00135 0 15.00040 0 15.00145 0 15.00035 0 1 1.442E-06 20.591E-06 15.00000 15.00145 0 15.00035 0 15.00140 0 15.00035 0 2 1.209E-06 17.265E-06 15.00000 15.00140 0 15.00035 0 15.00140 0 15.00035 0 3 1.371E-06 19.587E-06 15.00000 15.00145 0 15.00035 0 15.00145 0 15.00030 0 4 1.411E-06 20.157E-06 15.00000 15.00145 0 15.00035 0 15.00145 0 15.00035 0