SLAC Magnetic Measurements Date: 10-03-2022 Time: 19:06:11 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.000000, Y0=0.000000 Nominal Gap=150.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -2.744E-06 -39.193E-06 150.00000 150.00015 0 150.00005 0 150.00015 0 150.00010 0 1 -2.569E-06 -36.691E-06 150.00000 150.00015 0 150.00010 0 150.00015 0 150.00010 0 2 -2.686E-06 -38.367E-06 150.00000 150.00015 0 150.00010 0 150.00020 0 150.00005 0 3 -2.918E-06 -41.678E-06 150.00000 150.00020 0 150.00010 0 150.00010 0 150.00015 0 4 -2.714E-06 -38.762E-06 150.00000 150.00020 0 150.00010 0 150.00015 0 150.00010 0