SLAC Magnetic Measurements Date: 10-03-2022 Time: 18:08:26 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.000000, Y0=0.000000 Nominal Gap=30.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.449E-06 -6.409E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00015 0 1 -0.346E-06 -4.945E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00020 0 2 -0.640E-06 -9.142E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00020 0 3 -0.511E-06 -7.294E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00020 0 4 -0.389E-06 -5.549E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00015 0