SLAC Magnetic Measurements Date: 10-03-2022 Time: 17:14:28 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.000000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.609E-06 8.701E-06 10.00000 10.00035 0 10.00030 0 10.00030 0 10.00030 0 1 0.589E-06 8.416E-06 10.00000 10.00035 0 10.00030 0 10.00035 0 10.00030 0 2 0.577E-06 8.242E-06 10.00000 10.00035 0 10.00035 0 10.00035 0 10.00035 0 3 0.585E-06 8.361E-06 10.00000 10.00040 0 10.00030 0 10.00035 0 10.00035 0 4 0.554E-06 7.909E-06 10.00000 10.00040 0 10.00035 0 10.00040 0 10.00035 0