SLAC Magnetic Measurements Date: 10-03-2022 Time: 17:09:13 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.002000, Y0=0.000000 Nominal Gap=9.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.324E-06 4.624E-06 9.00000 9.00045 0 9.00050 0 9.00045 0 9.00050 0 1 0.019E-06 0.273E-06 9.00000 9.00045 0 9.00050 0 9.00045 0 9.00050 0 2 0.412E-06 5.884E-06 9.00000 9.00045 0 9.00050 0 9.00045 0 9.00050 0 3 0.498E-06 7.111E-06 9.00000 9.00045 0 9.00050 0 9.00050 0 9.00050 0 4 0.240E-06 3.421E-06 9.00000 9.00045 0 9.00050 0 9.00050 0 9.00045 0