SLAC Magnetic Measurements Date: 10-04-2022 Time: 12:02:36 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=0.002000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -5.967E-06 -85.222E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0 1 -5.648E-06 -80.674E-06 75.00000 75.00020 0 75.00010 0 75.00015 0 75.00020 0 2 -5.579E-06 -79.677E-06 75.00000 75.00020 0 75.00010 0 75.00015 0 75.00020 0 3 -5.548E-06 -79.248E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0 4 -5.491E-06 -78.429E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0