SLAC Magnetic Measurements Date: 10-04-2022 Time: 10:10:01 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.938E-06 27.679E-06 10.00000 10.00035 0 10.00035 0 10.00040 0 10.00035 0 1 1.815E-06 25.921E-06 10.00000 10.00040 0 10.00035 0 10.00040 0 10.00035 0 2 1.916E-06 27.366E-06 10.00000 10.00040 0 10.00035 0 10.00040 0 10.00035 0 3 1.821E-06 26.012E-06 10.00000 10.00040 0 10.00035 0 10.00040 0 10.00035 0 4 1.998E-06 28.537E-06 10.00000 10.00040 0 10.00035 0 10.00040 0 10.00035 0