SLAC Magnetic Measurements Date: 10-04-2022 Time: 09:54:53 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=9.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.778E-06 25.400E-06 9.00000 9.00045 0 9.00040 0 9.00040 0 9.00045 0 1 1.799E-06 25.700E-06 9.00000 9.00045 0 9.00040 0 9.00045 0 9.00040 0 2 1.726E-06 24.649E-06 9.00000 9.00040 0 9.00040 0 9.00045 0 9.00040 0 3 1.711E-06 24.435E-06 9.00000 9.00045 0 9.00040 0 9.00045 0 9.00040 0 4 1.900E-06 27.140E-06 9.00000 9.00045 0 9.00040 0 9.00045 0 9.00035 0