SLAC Magnetic Measurements Date: 10-04-2022 Time: 13:25:14 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 76 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=15.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 2.871E-06 41.003E-06 15.00000 15.00025 0 15.00005 0 15.00035 0 15.00005 0 1 2.800E-06 39.990E-06 15.00000 15.00060 0 15.00005 0 15.00065 0 15.00005 0 2 2.704E-06 38.616E-06 15.00000 15.00075 0 15.00010 0 15.00080 0 15.00005 0 3 2.742E-06 39.163E-06 15.00000 15.00085 0 15.00010 0 15.00090 0 15.00010 0 4 2.748E-06 39.256E-06 15.00000 15.00100 0 15.00020 0 15.00100 0 15.00020 0