SLAC Magnetic Measurements Date: 10-04-2022 Time: 13:09:46 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 76 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 2.548E-06 36.395E-06 10.00000 10.00010 0 10.00010 0 10.00015 0 10.00015 0 1 2.477E-06 35.376E-06 10.00000 10.00020 0 10.00020 0 10.00025 0 10.00020 0 2 2.709E-06 38.694E-06 10.00000 10.00025 0 10.00025 0 10.00025 0 10.00025 0 3 2.425E-06 34.630E-06 10.00000 10.00030 0 10.00025 0 10.00030 0 10.00025 0 4 2.553E-06 36.468E-06 10.00000 10.00030 0 10.00030 0 10.00030 0 10.00030 0