SLAC Magnetic Measurements Date: 10-04-2022 Time: 12:39:01 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 76 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=7.20 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 2.157E-06 30.808E-06 7.20000 7.19940 0 7.19970 0 7.19925 0 7.19970 0 1 2.296E-06 32.790E-06 7.20000 7.19870 0 7.19950 0 7.19865 0 7.19945 0 2 2.317E-06 33.099E-06 7.20000 7.19840 0 7.19930 0 7.19835 0 7.19925 0 3 2.280E-06 32.571E-06 7.20000 7.19820 0 7.19915 0 7.19815 0 7.19915 0 4 2.385E-06 34.071E-06 7.20000 7.19805 0 7.19905 0 7.19800 0 7.19905 0