SLAC Magnetic Measurements Date: 10-03-2022 Time: 12:25:07 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 73 Measurement Type: Long Coil Scans Operator: YL Comment: Check background Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=100.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -5.575E-06 -79.621E-06 100.00000 100.00030 0 100.00020 0 100.00030 0 100.00020 0 1 -5.588E-06 -79.808E-06 100.00000 100.00030 0 100.00020 0 100.00030 0 100.00020 0 2 -7.565E-06 -108.056E-06 100.00000 100.00025 0 100.00025 0 100.00025 0 100.00030 0 3 -5.373E-06 -76.749E-06 100.00000 100.00025 0 100.00030 0 100.00035 0 100.00020 0 4 -5.494E-06 -78.468E-06 100.00000 100.00030 0 100.00025 0 100.00030 0 100.00025 0